Raider™ Guidewire
The Raider™ Guidewire is a mid-tip load, non-tapered, polymer jacketed specialty wire with a unique tip designed to meet the demands of complex lesions and precise wire techniques.
Unmatched visibility
The Raider™ Guidewire features a 10 cm radiopaque tip compared to the Pilot™ 200 Guidewire’s 3 cm radiopaque tip. The Raider™ Guidewire’s extended radiopaque tip length is designed to promote precise positioning under fluoroscopy.
Superior tip load and penetration power
The Raider™ Guidewire is designed with a tip load and penetration power to stand up to tougher occlusions.2
Lubricious coating
Competitive support profile
|
MODEL |
SHAFT O.D. |
DISTAL TIP O.D. |
LENGTH |
CORE MATERIAL |
POLYMER JACKET LENGTH |
HYDROPHILIC COATING LENGTH |
COIL LENGTH |
RADIOPAQUE TIP LENGTH |
TIP SHAPE |
TIP LOAD |
|
7448 |
0.014” |
0.014” |
200 cm* |
Stainless Steel |
30 cm |
30 cm |
25 cm |
10 cm |
Straight |
4 g |
|
7449 |
0.014” |
0.014” |
300 cm |
Stainless Steel |
30 cm |
30 cm |
25 cm |
10 cm |
Straight |
4 g |
|
*190 cm was a previous length that may still be in distribution in select
geographies. |
||||||||||
- Based on manufacturer-reported radiopaque coil lengths—Pilot™ 200 Guidewire labeling.
- All values are based on bench test data, n = 15, performed by Teleflex. Bench test results may not be indicative of clinical performance.
- Penetration power refers to the tested tip load divided by the cross-sectional area of the distal tip.
- All values are based on bench test data and are analyzed with 95% confidence as a percentage of the means. Bench test results may not be indicative of clinical performance.
- Durability refers to lubricity as measured over time (25 cycles tested).
The Raider™ Guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature, including use in crossing or assisting in crossing de novo coronary chronic total occlusions (CTO).
CAUTION: Federal Law (U.S.A.) restricts this device to sale or use by or on the order of a physician.
Teleflex, the Teleflex logo, and Raider are trademarks or registered trademarks of Teleflex Incorporated or its affiliates in the U.S. and/or other countries. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Information in this material is not a substitute for the product Instructions for Use. Not all products may be available in all countries. Please contact your local representative.
© 2026 Teleflex Incorporated. All rights reserved. MC-004143 Rev 2.2 Revised: 03/2026.